cair Pro – Air Quality Monitor with CO₂
NuWave’s cair smart air quality monitor for office environments is designed to detect the presence of Volatile Organic Compound (VOCs) and monitoring particle concentration (Large and Fine particles) as well as environmental parameters (temperature and humidity).
Knowing and understanding what pollutants are in your environment is key to managing the health and comfort of everyone in your living space. If you are aware of what factors inside your living space can cause health symptoms you can take action.
The cair Pro indoor air quality monitor contains sensors that continuously collect information about the air quality in your living space and via its smartphone app it will alert you when levels of airborne contaminants (like animal dander, mould, toxins and pollen) are elevated. cair Pro includes an NDIR CO₂ sensor to provide information on ventilation levels in the living space – low CO₂ levels indicate good ventilation which is important for diluting pollutants in the air – including viruses, bacteria and other organisms which can become an issue in our lives.
Each cair Pro sensor is connected to a cloud database via local Wi-Fi connectivity and data can be exported in CSV format to e-mail for detailed offline analysis.
cair Pro monitors the following air quality parameters:
• Volatile Organic Compounds (VOCs)
• Carbon Dioxide (CO₂)
• Particle Concentration (Large & Fine Particles)
• Environmental Parameters (Temperature & Humidity)
cair Features
The air in your living space – at your fingertips
The cair Pro comes with a free app that lets you monitor your air quality from anywhere, anytime.
Using the compatible app you can view current air quality levels in your living space on your smartphone, track when you have an asthma or allergy issue and receive personalized app notifications when the air quality in your living space poses a potential problem. You can then take action using a set of recommendations provided via the app.

Specifications:
Performance (VOC Sensor)
Sensing Range | VOC’s measured in CO₂ equivalents (parts per million) | 450-2000 ppm |
Accuracy | Across full range | +/- 15 ppm |
Resolution | RMS noise (ppb equivalent) ©250ppb | 10ppm |
Warm-up time | To reach optimal detection performance | 5 mins |
Performance (Particle Sensor)
Output | For reference only – cannot count particles or measure quantitatively | pcs/ft³ |
No. of Channels | Small particle (1-2μm) and Large particle (3-10μm) | 2 |
Particle Sizes |
Range (approx) |
0.3μm – lOμm |
Accuracy |
Across Full Range |
+/-15% |
Warm-up time |
To reach optimal detection performance |
5 mins |
Performance (NDIR CO₂ Sensor)
Target Gas | Carbon dioxide (CO₂) |
Measurement Range | 0 to 5000 ppm / 0.04 to 2% Volume CO₂ |
Accuracy | +/-40ppm +/-3% of reading* |
Maintenance | Maintenance free |
Warm-up time | 1 minute |
* Please note: Accuracy is valid after a minimum of 3 weeks continuous use
Environment
Temperature range | Operating Temperature °C | 0 to 50°C |
Temperature range |
Storage Temperature °C | -25 to 50°C |
Humidity range | % RH continuous | 5 to 95% |
Inputs and Outputs
Input | 100-240V International Adapter | USB 5V, 1A (supplied) |
Power Consumption | 130mA @ 5V | – |
Wireless Outputs | WiFi 802.11/g/n@ 2.4Ghz | Data updates once per minute |