cair Air Quality Monitor
€129.27
NuWave’s cair smart air quality monitor for office environments is designed to detect the presence of Volatile Organic Compound (VOCs) and monitoring particle concentration (Large and Fine particles) as well as environmental parameters (temperature and humidity).
We spend roughly 25% of our time at work so managing air quality at the office is important! Indoor air can be 5 times more polluted than outdoor air and poor air quality at work can have an impact on our productivity and lead to symptoms such as eye, skin and airway irritation, headaches and fatigue.
NuWave’s cair smart air quality monitor for office environments is designed to detect the presence of Volatile Organic Compound (VOCs) and monitoring particle concentration (Large and Fine particles) as well as environmental parameters (temperature and humidity).
Each cair sensor is connected to a cloud database via local Wi-Fi connectivity and data can be exported in CSV format to e-mail for detailed offline analysis.
Typical Applications
• Office air quality monitoring
• Demand controlled ventilation monitoring
• VOC monitoring as part of building fit out
cair Features
cair sensor software – for commercial applications
Your cair sensor can be used with an app available on Google Play and the iOS App store. The app can be used to set up each sensor with your Wi-Fi network and one account permits multiple logins to the app for real time monitoring of sensor data.
For detailed analysis of sensor data, a web portal login provides functionality for commercial customers to download and analyse data offline. Data is sent by e-mail in CSV format.

SpecificationsPerformance (VOC Sensor)
Sensing Range | VOC’s measured in CO2 equivalents (parts per million) | 450-2000 ppm |
Accuracy | Across full range | +/- 15 ppm |
Resolution | RMS noise (ppb equivalent) ©250ppb | 10ppm |
Warm-up time | To reach optimal detection performance | 5 mins |
Performance (Particle Sensor)
Output | For reference only – cannot count particles or measure quantitatively | pcs/ft3 |
No. of Channels | Small particle (1-2μm) and Large particle (3-10μm) | 2 |
Particle Sizes |
Range (approx) |
0.3μm – lOμm |
Accuracy |
Across Full Range |
+/-15% |
Warm-up time |
To reach optimal detection performance |
5 mins |
Environment
Temperature range | Operating Temperature °C | 0 to 50°C |
Temperature range |
Storage Temperature °C | -25 to 50°C |
Humidity range | % RH continuous | 5 to 95% |
Inputs and Outputs
Input | 100-240V International Adapter | USB 5V, 1A (supplied) |
Power Consumption | 130mA @ 5V | – |
Wireless Outputs | WiFi 802.11/g/n@ 2.4Ghz | Data updates once per minute |